{"id":209,"date":"2018-04-18T15:42:45","date_gmt":"2018-04-18T13:42:45","guid":{"rendered":"http:\/\/www.parsum.de\/en\/?page_id=209"},"modified":"2018-06-05T12:29:35","modified_gmt":"2018-06-05T10:29:35","slug":"accessories-process-interface","status":"publish","type":"page","link":"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/","title":{"rendered":"Accessories \/ process interface"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row css=&#8221;.vc_custom_1508315877245{padding-top: 70px !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_column_text]A wide range of accessories, such as inline dispersers and cleaning cells, provide a so-called \u201cprocess interface\u201d for adapting the measurement probe to different conditions within the process.<\/p>\n<p>The option of dispersing the particle flow within the process vessel sets Parsum probes apart from other inline measuring systems. Inline dispersing is the only way of ensuring particle size determination in damp, sticky, electrostatically charged or otherwise complicated materials in a reliable manner and in a way that is comparable with laboratory processes.<\/p>\n<p>The cleaning cells use compressed air to keep the optics free of particle deposits, thereby significantly reducing the cleaning frequencies. Inline dispersers dilute the particle flow using compressed air, while simultaneously preventing deposits and blockages on the optics. A hard-chrome-plated protective tube means that the probe can be used even with particularly abrasive materials such as silicon carbide or corundum.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;212&#8243; img_size=&#8221;full&#8221; onclick=&#8221;link_image&#8221; lazy_loading=&#8221;true&#8221;][\/vc_column][\/vc_row][vc_row bg_type=&#8221;bg_color&#8221; bg_override=&#8221;full&#8221; css=&#8221;.vc_custom_1508754659784{margin-top: 30px !important;padding-top: 30px !important;padding-bottom: 50px !important;}&#8221; bg_color_value=&#8221;#f5f5f5&#8243;][vc_column][vc_row_inner equal_height=&#8221;yes&#8221; gap=&#8221;25&#8243;][vc_column_inner width=&#8221;1\/4&#8243; css=&#8221;.vc_custom_1508754687452{padding-top: 35px !important;padding-right: 15px !important;padding-bottom: 15px !important;padding-left: 15px !important;background-color: #ffffff !important;}&#8221;]<div id=\"ultimate-heading-54526a2fbb48a367f\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-54526a2fbb48a367f uvc-9454 accent-border-color\" data-hspacer=\"line_only\"  data-halign=\"center\" style=\"text-align:center\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-54526a2fbb48a367f h2'  data-responsive-json-new='{\"font-size\":\"desktop:30px;\",\"line-height\":\"desktop:36px;\"}' ><h2 style=\"font-weight:bold;margin-bottom:5px;\">SZ11 cleaning cell<\/h2><\/div><div class=\"uvc-heading-spacer line_only\" style=\"margin-bottom:30px;height:5px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:5px;border-color:;width:200px;\"><\/span><\/div><\/div><div class=\"standard-arrow bullet-top\"><ul>\n<li>Suitable for use with free-falling or pneumatically conveyed particles or granulates with low fine contents; individual larger agglomerates may be present; suitable for use with spray measurements<\/li>\n<li>Measuring volume: 10\u00a0mm<\/li>\n<li>Particle-size range: 200 \u00b5m\u20136000\u00a0\u00b5m<\/li>\n<li>Mean particle size &gt;500\u00a0\u00b5m<\/li>\n<li><a href=\"https:\/\/www.parsum.de\/wp-content\/uploads\/2018\/06\/Parsum-data-sheet-disperser-En-05-18.pdf\" target=\"_blank\" rel=\"noopener\">Datasheet download<\/a><\/li>\n<\/ul>\n<\/div>[\/vc_column_inner][vc_column_inner width=&#8221;1\/4&#8243; css=&#8221;.vc_custom_1508754700446{padding-top: 35px !important;padding-right: 15px !important;padding-bottom: 15px !important;padding-left: 15px !important;background-color: #ffffff !important;}&#8221;]<div id=\"ultimate-heading-98936a2fbb48a37b3\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-98936a2fbb48a37b3 uvc-7633 accent-border-color\" data-hspacer=\"line_only\"  data-halign=\"center\" style=\"text-align:center\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-98936a2fbb48a37b3 h2'  data-responsive-json-new='{\"font-size\":\"desktop:30px;\",\"line-height\":\"desktop:36px;\"}' ><h2 style=\"font-weight:bold;margin-bottom:5px;\">SZ20 cleaning cell<\/h2><\/div><div class=\"uvc-heading-spacer line_only\" style=\"margin-bottom:30px;height:5px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:5px;border-color:;width:200px;\"><\/span><\/div><\/div><div class=\"standard-arrow bullet-top\"><ul>\n<li>Suitable for use in products with low fine contents in freefall; individual larger agglomerates may be present;<\/li>\n<li>Measuring volume: 6\u00a0mm<\/li>\n<li>Particle-size range: 50 \u00b5m\u20132500\u00a0\u00b5m<\/li>\n<li>Mean particle size &gt;200\u00a0\u00b5m<\/li>\n<li><a href=\"https:\/\/www.parsum.de\/wp-content\/uploads\/2018\/06\/Parsum-data-sheet-disperser-En-05-18.pdf\" target=\"_blank\" rel=\"noopener\">Datasheet download<\/a><\/li>\n<\/ul>\n<\/div>[\/vc_column_inner][vc_column_inner width=&#8221;1\/4&#8243; css=&#8221;.vc_custom_1508754711830{padding-top: 35px !important;padding-right: 15px !important;padding-bottom: 15px !important;padding-left: 15px !important;background-color: #ffffff !important;}&#8221;]<div id=\"ultimate-heading-85586a2fbb48a386f\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-85586a2fbb48a386f uvc-7659 accent-border-color\" data-hspacer=\"line_only\"  data-halign=\"center\" style=\"text-align:center\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-85586a2fbb48a386f h2'  data-responsive-json-new='{\"font-size\":\"desktop:30px;\",\"line-height\":\"desktop:36px;\"}' ><h2 style=\"font-weight:bold;margin-bottom:5px;\">D24 inline disperser<\/h2><\/div><div class=\"uvc-heading-spacer line_only\" style=\"margin-bottom:30px;height:5px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:5px;border-color:;width:200px;\"><\/span><\/div><\/div><div class=\"standard-arrow bullet-top\"><ul>\n<li>Used for products with high fine contents, in dense particle streams or in fluidised beds with high concentrations<\/li>\n<li>Measuring aperture: 3.8\u00a0mm<\/li>\n<li>Particle-size range: 50 \u00b5m\u20132000\u00a0\u00b5m<\/li>\n<li>Mean particle size &gt;50\u00a0\u00b5m to 1200\u00a0\u00b5m<\/li>\n<li>Air supply: internal\/external<\/li>\n<li>Also available with Teflon coating<\/li>\n<li><a href=\"https:\/\/www.parsum.de\/wp-content\/uploads\/2018\/06\/Parsum-data-sheet-disperser-En-05-18.pdf\" target=\"_blank\" rel=\"noopener\">Datasheet download<\/a><\/li>\n<\/ul>\n<\/div>[\/vc_column_inner][vc_column_inner width=&#8221;1\/4&#8243; css=&#8221;.vc_custom_1508757598136{padding-top: 35px !important;padding-right: 15px !important;padding-bottom: 15px !important;padding-left: 15px !important;background-color: #ffffff !important;}&#8221;]<div id=\"ultimate-heading-55786a2fbb48a3929\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-55786a2fbb48a3929 uvc-6559 accent-border-color\" data-hspacer=\"line_only\"  data-halign=\"center\" style=\"text-align:center\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-55786a2fbb48a3929 h2'  data-responsive-json-new='{\"font-size\":\"desktop:30px;\",\"line-height\":\"desktop:36px;\"}' ><h2 style=\"font-weight:bold;margin-bottom:5px;\">D12 inline disperser<\/h2><\/div><div class=\"uvc-heading-spacer line_only\" style=\"margin-bottom:30px;height:5px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:5px;border-color:;width:200px;\"><\/span><\/div><\/div><div class=\"standard-arrow bullet-top\"><ul>\n<li>Used for products with very broad distributions and oversized content, such as in high-concentration fluidised beds with fine contents and large agglomerates or ground products with fine and coarse contents<\/li>\n<li>Measuring aperture: 7\u00a0mm<\/li>\n<li>Particle-size range: 50 \u00b5m\u20136000\u00a0\u00b5m<\/li>\n<li>Mean particle size: 1000 \u00b5m\u20134000\u00a0\u00b5m<\/li>\n<li>Air supply: internal\/external<\/li>\n<li>Also available with Teflon coating<\/li>\n<li><a href=\"https:\/\/www.parsum.de\/wp-content\/uploads\/2018\/06\/Parsum-data-sheet-disperser-En-05-18.pdf\" target=\"_blank\" rel=\"noopener\">Datasheet download<\/a><\/li>\n<\/ul>\n<\/div>[\/vc_column_inner][\/vc_row_inner][vc_row_inner equal_height=&#8221;yes&#8221; gap=&#8221;25&#8243;][vc_column_inner width=&#8221;1\/3&#8243; css=&#8221;.vc_custom_1508754687452{padding-top: 35px !important;padding-right: 15px !important;padding-bottom: 15px !important;padding-left: 15px !important;background-color: #ffffff !important;}&#8221;]<div id=\"ultimate-heading-27446a2fbb48a39ec\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-27446a2fbb48a39ec uvc-5533 accent-border-color\" data-hspacer=\"line_only\"  data-halign=\"center\" style=\"text-align:center\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-27446a2fbb48a39ec h2'  data-responsive-json-new='{\"font-size\":\"desktop:30px;\",\"line-height\":\"desktop:36px;\"}' ><h2 style=\"font-weight:bold;margin-bottom:5px;\">ES1 sampling probe<\/h2><\/div><div class=\"uvc-heading-spacer line_only\" style=\"margin-bottom:30px;height:5px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:5px;border-color:;width:200px;\"><\/span><\/div><\/div><div class=\"standard-arrow bullet-top\"><ul>\n<li>The ES1 sampling probe fits all probe models and was specifically developed for applications where the entire probe cannot be introduced into the process. This is the case with very small process containers, very small material quantities, bulk material and situations with poor accessibility in general.<\/li>\n<li><a href=\"https:\/\/www.parsum.de\/wp-content\/uploads\/2018\/06\/Parsum-data-sheet-sampling-probe-ES-1-En-05-18.pdf\" target=\"_blank\" rel=\"noopener\">Datasheet download<\/a><\/li>\n<\/ul>\n<\/div>[vc_toggle title=&#8221;Additional information&#8221; size=&#8221;sm&#8221; custom_font_container=&#8221;tag:h5|text_align:left|color:%23009a9b&#8221; custom_use_theme_fonts=&#8221;yes&#8221; use_custom_heading=&#8221;true&#8221;]<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-213\" src=\"https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/entnahmesonde.jpg\" alt=\"\" width=\"284\" height=\"284\" srcset=\"https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/entnahmesonde.jpg 284w, https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/entnahmesonde-150x150.jpg 150w\" sizes=\"auto, (max-width: 284px) 100vw, 284px\" \/>To carry out the measurement, compressed air is used to extract the material from the process chamber or bulk material, with the option of then feeding it back in once the measurement is complete. As well as transporting the material, special nozzle arrangements within the probe tube also ensure a gentle dispersion of the material. This treatment ensures that the material can be reliably measured even under difficult conditions.<\/p>\n<p>There is also the option of an additional extension for returning the material to the process chamber using compressed air.<\/p>\n<p>To prevent blockages, the inlet can also be automatically blown out by means of an air pulse.[\/vc_toggle][vc_toggle title=&#8221;Technical details&#8221; size=&#8221;sm&#8221; custom_font_container=&#8221;tag:h5|text_align:left|color:%23009a9b&#8221; custom_use_theme_fonts=&#8221;yes&#8221; use_custom_heading=&#8221;true&#8221;]<strong>Accessories for probe models:<\/strong> IPP 70, 75 and 80<br \/>\n<strong>Particle size measurement range:<\/strong> 50 \u00b5m\u20131000 \u00b5m<br \/>\n<strong>Particle velocity measurement range:<\/strong> 0.01 m\/s\u2013100 m\/s<br \/>\n<strong>Products:<\/strong> Solid particles from processes or bulk material<br \/>\n<strong>Suction tube dimensions (L\/D):<\/strong> Length 90 mm, outer diameter 6 mm \/ inner diameter 3 mm<br \/>\n<strong>Assembly of measuring body with suction pump:<\/strong> Screw connection in the probe measuring body and self-adjusting clamp on the circumference of the probe tube<br \/>\n<strong>Materials coming into contact with product:<\/strong> Stainless steel (L316)<br \/>\n<strong>Weight:<\/strong> approx. 300 g[\/vc_toggle][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243; css=&#8221;.vc_custom_1508754700446{padding-top: 35px !important;padding-right: 15px !important;padding-bottom: 15px !important;padding-left: 15px !important;background-color: #ffffff !important;}&#8221;]<div id=\"ultimate-heading-94746a2fbb48a3a98\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-94746a2fbb48a3a98 uvc-4384 accent-border-color\" data-hspacer=\"line_only\"  data-halign=\"center\" style=\"text-align:center\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-94746a2fbb48a3a98 h2'  data-responsive-json-new='{\"font-size\":\"desktop:30px;\",\"line-height\":\"desktop:36px;\"}' ><h2 style=\"font-weight:bold;margin-bottom:5px;\">FZ1 liquid-measuring cell<\/h2><\/div><div class=\"uvc-heading-spacer line_only\" style=\"margin-bottom:30px;height:5px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:5px;border-color:;width:200px;\"><\/span><\/div><\/div><div class=\"standard-arrow bullet-top\"><ul>\n<li>The FZ1 liquid-measuring cell is an accessory part that can be used with all Parsum probes in the IPP 70 and IPP 80 series. This cell makes it possible to measure the particle size distribution in a fluid flowing through a glass tube.<\/li>\n<li><a href=\"https:\/\/www.parsum.de\/wp-content\/uploads\/2018\/06\/Parsum-data-sheet-liquid-cell-En-05-18.pdf\" target=\"_blank\" rel=\"noopener\">Datasheet download<\/a><\/li>\n<\/ul>\n<\/div>[vc_toggle title=&#8221;Additional information&#8221; size=&#8221;sm&#8221; custom_font_container=&#8221;tag:h5|text_align:left|color:%23009a9b&#8221; custom_use_theme_fonts=&#8221;yes&#8221; use_custom_heading=&#8221;true&#8221;]<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-214\" src=\"https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/fluessigmesszelle.jpg\" alt=\"\" width=\"284\" height=\"284\" srcset=\"https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/fluessigmesszelle.jpg 284w, https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/fluessigmesszelle-150x150.jpg 150w\" sizes=\"auto, (max-width: 284px) 100vw, 284px\" \/>In this way, the probe does not come into contact with the product. The measurement is carried out through the glass tube without contamination. The measurement can be carried out continuously online by extracting the liquid from a process vessel or process line in a bypass flow, and feeding it through the probe\u2019s measuring volume. The extracted product can also be diluted with water or other liquids following extraction before passing through the measuring volume. The glass tube in the measuring volume can be adjusted either by eccentric rotation, manually using a lever.<\/p>\n<p>Parsum provides you with a complete installation that has been adapted to your specific measuring conditions, together with a sampling system, dilution and pump (if necessary).[\/vc_toggle][vc_toggle title=&#8221;Technical details&#8221; size=&#8221;sm&#8221; custom_font_container=&#8221;tag:h5|text_align:left|color:%23009a9b&#8221; custom_use_theme_fonts=&#8221;yes&#8221; use_custom_heading=&#8221;true&#8221;]<strong>Particle size measurement range:<\/strong> 50 \u00b5m\u20132000 \u00b5m or larger<br \/>\n<strong>Particle velocity: measurement range:<\/strong> 0.01 m\/s to approx. 5 m\/s<br \/>\n<strong>Products:<\/strong> Solid or liquid particles in transparent liquids<br \/>\n<strong>Dimensions:<\/strong> approx. 45\u00d716\u00d740 (with mounting bracket)<br \/>\n<strong>Assembly:<\/strong> Clamp\/screw connection in probe\u2019s measuring volume<br \/>\n<strong>Measuring tube:<\/strong> Glass, outer diameter = 6 mm, inner diameter = 5 mm, length approx. 70 mm<br \/>\n<strong>Tube connection:<\/strong> Hose connection, depressurised<br \/>\n<strong>Materials coming into contact with product:<\/strong> Glass (other tube materials possible)<br \/>\n<strong>Weight:<\/strong> approx. 50 g<br \/>\n<strong>Options:<\/strong> Design pressure resistant up to 4 bar; larger tube diameter (up to max. inner diameter of 8 mm)[\/vc_toggle][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243; css=&#8221;.vc_custom_1508754711830{padding-top: 35px !important;padding-right: 15px !important;padding-bottom: 15px !important;padding-left: 15px !important;background-color: #ffffff !important;}&#8221;]<div id=\"ultimate-heading-28226a2fbb48a3b61\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-28226a2fbb48a3b61 uvc-1465 accent-border-color\" data-hspacer=\"line_only\"  data-halign=\"center\" style=\"text-align:center\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-28226a2fbb48a3b61 h2'  data-responsive-json-new='{\"font-size\":\"desktop:30px;\",\"line-height\":\"desktop:36px;\"}' ><h2 style=\"font-weight:bold;margin-bottom:5px;\">At-line particle-measuring system<\/h2><\/div><div class=\"uvc-heading-spacer line_only\" style=\"margin-bottom:30px;height:5px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:5px;border-color:;width:200px;\"><\/span><\/div><\/div><div class=\"standard-arrow bullet-top\"><ul>\n<li>The at-line particle-measuring system is designed for use near the production location and allows for the quick and easy analysis of particle sizes of samples from various sampling points.<\/li>\n<li><a href=\"https:\/\/www.parsum.de\/wp-content\/uploads\/2018\/06\/Parsum-data-sheet-at-line-En-05-18.pdf\" target=\"_blank\" rel=\"noopener\">Datasheet download<\/a><\/li>\n<\/ul>\n<\/div>[vc_toggle title=&#8221;Additional information&#8221; size=&#8221;sm&#8221; custom_font_container=&#8221;tag:h5|text_align:left|color:%23009a9b&#8221; custom_use_theme_fonts=&#8221;yes&#8221; use_custom_heading=&#8221;true&#8221;]<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-215\" src=\"https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/atline.jpg\" alt=\"\" width=\"284\" height=\"284\" srcset=\"https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/atline.jpg 284w, https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/atline-150x150.jpg 150w\" sizes=\"auto, (max-width: 284px) 100vw, 284px\" \/>From a cost perspective, it is therefore the ideal compromise for the simultaneous monitoring of several production lines or sampling points where the inline process-monitoring method is too complex or not feasible.<\/p>\n<p>The at-line system is made completely of stainless steel and has two clips for the attachment of an IPP 70 or IPP 80 inline particle-measuring probe. The cover plate features a vibratory conveyor for metered sample feeding with infinitely variable transport-speed adjustment.<\/p>\n<p>This makes it possible to set up a complete particle-measuring station in combination with the particle-measuring probe, a measuring PC including IPP measuring software and accessories. The technical specifications of the IPP 70 and IPP 80 inline particle-measuring probes can be found in the appropriate datasheets. There is also the option of connecting a suction device for additional dispersion or disposal of the sample material after the measurement has been performed.[\/vc_toggle][vc_toggle title=&#8221;Technical details&#8221; size=&#8221;sm&#8221; custom_font_container=&#8221;tag:h5|text_align:left|color:%23009a9b&#8221; custom_use_theme_fonts=&#8221;yes&#8221; use_custom_heading=&#8221;true&#8221;]<strong>Measuring system as accessory:<\/strong> IPP 70-S, IPP 70-Se, IPP 75-S or IPP 80-P<br \/>\n<strong>Particle size measurement range:<\/strong> 50&#8230;6000 \u00b5m<br \/>\n<strong>Particle velocity measurement range:<\/strong> 0.01\u2026100 m\/s<br \/>\n<strong>Products:<\/strong> Powder, granulates, bulk goods&#8230;<br \/>\n<strong>Frame dimensions (W\/H\/D):<\/strong> 450 x 330 x 350 mm<br \/>\n<strong>Vibratory conveyor connection:<\/strong> 110\/230 VAC, 50\/60 Hz<br \/>\n<strong>Probe mount dimensions:<\/strong> 25 mm (for IPP 70, IPP 75 or IPP 80 probe)<br \/>\n<strong>Sample feed:<\/strong> Funnel with downpipe, 6 mm diameter (optional 8 mm)<br \/>\n<strong>Additional sample dispersion:<\/strong> D24, D12 disperser and\/or suction dust extractor for example[\/vc_toggle][vc_toggle title=&#8221;Accessories&#8221; size=&#8221;sm&#8221; custom_font_container=&#8221;tag:h5|text_align:left|color:%23009a9b&#8221; custom_use_theme_fonts=&#8221;yes&#8221; use_custom_heading=&#8221;true&#8221;]<strong>Measurement probe:<\/strong> IPP 70-S, IPP 70-Se, IPP 75-S or IPP 80-P<br \/>\n<strong>Measuring PC \/ software:<\/strong> Measuring PC with measuring software installed for the evaluation and presentation of the measured values<\/p>\n<p><strong>Options:<\/strong><br \/>\n<strong>At-line versions:<\/strong> The frame for the at-line system can also be supplied with a suction dust extractor<br \/>\n<strong>D24 disperser:<\/strong> for high loads \/ high fine contents \u2013 up to 2000 \u00b5m particles, clearance 3.8 mm<br \/>\n<strong>D12 disperser:<\/strong> as for D24, but also for larger particles &gt;2000 \u00b5m, clearance 7.5 mm<br \/>\n<strong>SZ11, SZ20-4 cleaning cells:<\/strong> for low loads for cleaning the probe optics without diluting the particle stream<br \/>\n<strong>Compressed-air unit:<\/strong> Compressed-air supply for the probe when using dispersers or cleaning cells[\/vc_toggle][\/vc_column_inner][\/vc_row_inner][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1508315877245{padding-top: 70px !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_column_text]A wide range of accessories, such as inline dispersers and cleaning cells, provide a so-called \u201cprocess interface\u201d for adapting the measurement probe to different conditions within the process. The option of dispersing the particle flow within the process vessel sets Parsum probes apart from other inline measuring systems. Inline dispersing is&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":45,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-209","page","type-page","status-publish","hentry","description-off"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Accessories \/ process interface - Parsum EN<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Accessories \/ process interface - Parsum EN\" \/>\n<meta property=\"og:description\" content=\"[vc_row css=&#8221;.vc_custom_1508315877245{padding-top: 70px !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_column_text]A wide range of accessories, such as inline dispersers and cleaning cells, provide a so-called \u201cprocess interface\u201d for adapting the measurement probe to different conditions within the process. The option of dispersing the particle flow within the process vessel sets Parsum probes apart from other inline measuring systems. Inline dispersing is&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/\" \/>\n<meta property=\"og:site_name\" content=\"Parsum EN\" \/>\n<meta property=\"article:modified_time\" content=\"2018-06-05T10:29:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/entnahmesonde.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"11 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/\",\"url\":\"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/\",\"name\":\"Accessories \/ process interface - Parsum EN\",\"isPartOf\":{\"@id\":\"https:\/\/www.parsum.de\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/entnahmesonde.jpg\",\"datePublished\":\"2018-04-18T13:42:45+00:00\",\"dateModified\":\"2018-06-05T10:29:35+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/#primaryimage\",\"url\":\"https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/entnahmesonde.jpg\",\"contentUrl\":\"https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/entnahmesonde.jpg\",\"width\":284,\"height\":284},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/www.parsum.de\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Particle probes\",\"item\":\"https:\/\/www.parsum.de\/en\/particle-probes\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Accessories \/ process interface\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.parsum.de\/en\/#website\",\"url\":\"https:\/\/www.parsum.de\/en\/\",\"name\":\"Parsum EN\",\"description\":\"Gesellschaft f\u00fcr Partikel-, Str\u00f6mungs- und Umweltme\u00dftechnik mbH\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.parsum.de\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Accessories \/ process interface - Parsum EN","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/","og_locale":"en_GB","og_type":"article","og_title":"Accessories \/ process interface - Parsum EN","og_description":"[vc_row css=&#8221;.vc_custom_1508315877245{padding-top: 70px !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_column_text]A wide range of accessories, such as inline dispersers and cleaning cells, provide a so-called \u201cprocess interface\u201d for adapting the measurement probe to different conditions within the process. The option of dispersing the particle flow within the process vessel sets Parsum probes apart from other inline measuring systems. Inline dispersing is&hellip;","og_url":"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/","og_site_name":"Parsum EN","article_modified_time":"2018-06-05T10:29:35+00:00","og_image":[{"url":"https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/entnahmesonde.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"11 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/","url":"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/","name":"Accessories \/ process interface - Parsum EN","isPartOf":{"@id":"https:\/\/www.parsum.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/#primaryimage"},"image":{"@id":"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/#primaryimage"},"thumbnailUrl":"https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/entnahmesonde.jpg","datePublished":"2018-04-18T13:42:45+00:00","dateModified":"2018-06-05T10:29:35+00:00","breadcrumb":{"@id":"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/#primaryimage","url":"https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/entnahmesonde.jpg","contentUrl":"https:\/\/www.parsum.de\/en\/wp-content\/uploads\/sites\/2\/2018\/04\/entnahmesonde.jpg","width":284,"height":284},{"@type":"BreadcrumbList","@id":"https:\/\/www.parsum.de\/en\/particle-probes\/accessories-process-interface\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.parsum.de\/en\/"},{"@type":"ListItem","position":2,"name":"Particle probes","item":"https:\/\/www.parsum.de\/en\/particle-probes\/"},{"@type":"ListItem","position":3,"name":"Accessories \/ process interface"}]},{"@type":"WebSite","@id":"https:\/\/www.parsum.de\/en\/#website","url":"https:\/\/www.parsum.de\/en\/","name":"Parsum EN","description":"Gesellschaft f\u00fcr Partikel-, Str\u00f6mungs- und Umweltme\u00dftechnik mbH","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.parsum.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"}]}},"_links":{"self":[{"href":"https:\/\/www.parsum.de\/en\/wp-json\/wp\/v2\/pages\/209","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.parsum.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.parsum.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.parsum.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.parsum.de\/en\/wp-json\/wp\/v2\/comments?post=209"}],"version-history":[{"count":6,"href":"https:\/\/www.parsum.de\/en\/wp-json\/wp\/v2\/pages\/209\/revisions"}],"predecessor-version":[{"id":347,"href":"https:\/\/www.parsum.de\/en\/wp-json\/wp\/v2\/pages\/209\/revisions\/347"}],"up":[{"embeddable":true,"href":"https:\/\/www.parsum.de\/en\/wp-json\/wp\/v2\/pages\/45"}],"wp:attachment":[{"href":"https:\/\/www.parsum.de\/en\/wp-json\/wp\/v2\/media?parent=209"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}